Sample collection and preservation
Good sample collection and preservation methods are crucial to the success of DNA extraction, and particular care and attention are especially needed for the collection and preservation of precious samples.


Animal tissue samples:
l Large tissue samples, cut into small pieces after collection, washed 2-3 times with PBS, and stored in sterile tubes;
l Respiratory tract samples are collected by dipping a cotton swab, and after sampling is completed, they should be immediately placed in phosphate-buffered saline;
l After blood samples are collected, anticoagulant must be added immediately, and the samples should be inserted upright into the sample box.
Plant tissue samples:
l When collecting plant samples, priority should be given to parts with vigorous cell division and higher nucleic acid content, such as young and tender parts of the plant;
l When collecting plant samples, it is recommended to use sterile water or 75% ethanol to wipe and rinse them, then use absorbent paper to dry the liquid on the sample surface.
Cell sample:
l After collecting the precipitate by centrifugation, it is ready for use.
In most cases, freshly prepared samples should be used for subsequent experiments whenever possible to achieve the best results. However, the objective reality is that newly collected tissue samples cannot be immediately processed.DNA extraction: for short-term storage and transportation, it can be kept at -20°C to 0°C; for long-term storage, it can be directly snap-frozen with liquid nitrogen and stored at -80°C for six months.
DNA extraction and purification
This protocol uses phenolic reagents to denature proteins in order to lyse the sample, followed by phenol/Chloroform extraction, followed by anhydrous ethanol precipitation. The role of chloroform is to remove excess phenol and promote the separation of the aqueous phase from the organic phase. This extraction method requires multiple centrifugations, and the steps are relatively cumbersome and prone to cross-contamination. In addition, because residual organic solvents such as phenol/chloroform will be introduced into the final product, they may inhibit subsequent PCR experiments.
It separates by adding various proteases to remove protein impurities.DNA, effectively avoiding reagent contamination to obtain high-yield and high-purity DNA, but the disadvantage is that the process of digesting protease is time-consuming and the purity is unstable.
This scheme involves dehydrating the phosphodiester backbone in DNA molecules under the action of chaotropic salts, thereby exposing the phosphate groups and allowing reversible adsorption to silica gel. The silica medium adsorption purification method can force the lysate through the filter membrane by centrifugation and vacuum pressure, enabling effective extraction of trace amounts of DNA. Electrostatic forces and hydrogen bonds play key roles in the adsorption between silica gel and nucleic acids. This method has certain limitations regarding the chain length of deoxyribonucleic acid; smaller DNA fragments (<100 bp) are not easily and effectively adsorbed onto the medium.
This method coats a purification medium onto the surface of nanoscale magnetic beads. Through the adsorption of DNA by the medium, under the action of an externally applied magnetic field, DNA attaches to the magnetic beads and moves in a directed manner, thereby achieving the separation of nucleic acids from other substances.
Compared with other methods, the magnetic bead method has the following advantages:
l Fast separation: magnetic separation takes only a few seconds;
l High extraction sensitivity: even trace amounts of samples can be purified and separated;
l High purity: nucleic acids are completely separated from impurities;
l High extraction yield: each milligram of magnetic beads can adsorb approximately 500 μg of DNA;
l High-throughput extraction: can simultaneously complete the extraction of hundreds of samples;
l Environmentally friendly and non-toxic: The extraction formula contains no toxic ingredients.
PCR amplification
PCR, also known as polymerase chain reaction, has a basic principle similar to the natural DNA replication process, and its specificity depends on oligonucleotide primers complementary to the two ends of the target sequence. This technology can amplify a specific target DNA fragment by a high order of magnitude from a mixture called template DNA. There are many sources of templates. In addition to extracting genomic DNA from cells as mentioned above, there is also cDNA reverse-transcribed from RNA, etc.

A PCR reaction needs to include the following components: DNA template, forward and reverse primers, dNTPs, reaction buffer, DNA polymerase, etc. Usually, commercial reagents pre-mix all components except the DNA template and the forward and reverse primers to facilitate scientific research use. The most important things to pay attention to in PCR experiments are primer design and reaction program setup. Generally, primers are designed using platforms such as Premier 5 or NCBI online design.
Primer design considerations
l Select C or G as the last base at the 3' end of the primer;
l The last 8 bases at the 3' end of the primer should avoid consecutive mismatches;
l Avoid hairpin structures at the 3' end of primers as much as possible;
l The primer Tm value should be controlled between 55°C and 65°C;
l The additional primer sequence, i.e., the sequence that is not paired with the template, should not be included in the calculation of the primer Tm value;
l Keep the primer GC content between 40% and 60%;
l The Tm values and GC content of forward and reverse primers should be as consistent as possible.


PCR product identification and purification
PCR products can be identified for quality using agarose gel electrophoresis technology, including the length, yield, and specificity of the obtained fragments.
l The target band from gel electrophoresis can be recovered using a DNA gel extraction kit.Collect the target DNA;
l PCR reaction products can also be directly purified using a PCR product cleanup kitPurify for downstream experiments.
Furthermore, to obtain detailed information on the DNA base sequence of the product, the sample can be sent to a sequencing company for sequencing.

PCR optimization strategies

The company you send out to design and synthesize primers will provide your oligonucleotide primers on the specification sheet. Tm, but we found that different companies provide significantly different Tm values based on the calculation methods they use. Here, we recommend IDT website's primer design tool OligoAnalyzer, which is very useful for optimizing annealing temperature. The Tm calculation formula is as follows:
Tm= 2(A+T) + 4(G+C)
where A, T, G, and C represent the corresponding number of bases in your primer sequence
The salt concentration, pH value, and primer concentration of Tm and buffer are related, but most people rarely consider these. Most people will tell you that to prevent the formation of primer dimers, it is recommended that the annealing temperature be at least 10°C higher than the Tm value. The OligoAnalyzer tool also takes into account the dimer structure of template DNA when designing primers. However, I suggest setting the annealing temperature 3°C lower than the lowest Tm of your two primers. For example, if your forward primer Tm is 62°C and your reverse primer Tm is 61°C, then set their annealing temperature to 58°C.
If you have a PCR instrument with gradient amplification function and a sufficient amount of template, you can perform two to three replicate experiments. I recommend setting a range of annealing temperatures for the experiment and evaluating the effect of each temperature.
In the first few cycles ofSet a higher annealing temperature in the PCR reaction. After each cycle (or two cycles, or three cycles), the annealing temperature Ta decreases by 1–2°C.
So, how do you do it specifically? Using the above example, where the Tm values of the two primers are 62°C and 61°C respectively, I would set the annealing temperature Ta to 63°C for the first two cycles, 62°C for the next two cycles, then 61°C, 60°C, and 59°C, for a total of 10 cycles. Then perform 25 cycles at 58°C. The advantage of this technique is that the first few cycles are very stringent, so it is unlikely that any nonspecific amplification will occur. At the same time, as the annealing temperature becomes more permissive for primer binding, the PCR tube acts like a reservoir with a certain amount of target amplicon, and when the reservoir already contains a sufficient amount of target amplicon, the target amplicon can win the competition with primers for nonspecific sequences!
The premise of the above experiment is to ensure that your PCR instrument can accurately and effectively adjust the temperature. We can understand how much time is wasted optimizing PCR conditions on a PCR instrument that does not work properly. Generally speaking, if your PCR instrument is not working properly, your PCR reaction may take longer than usual. So when you perform a PCR reaction, make sure that every step works! This includes your machine, the conditions you set, as well as the reaction conditions and reaction components (i.e., the primers, template, and buffer conditions you have previously validated).
The template quality required for PCR will be very high! At the same time, excessive DNA template content may reduce the specificity of the reaction and increase the amplification of unnecessary products. Primer PCR reactions are very sensitive, so use as low a template concentration as possible. Our recommended template amounts:
Plasmid DNA template no more than 1 ng;
cDNA: 10–40 ng;
Genomic DNA: 1 μg.
Have you ever wondered who came up with the PCR reaction conditions and methods, such that the denaturation and annealing times have always remained consistent, and only the extension time can be adjusted according to the size of your amplification? The general rule of thumb is that you need 60 seconds of extension time for every 1 kb amplified (depending on the efficiency of the polymerase you choose). For example, if you amplify a 2 kb fragment, you need to design an extension time of 120 seconds. For shorter products, shorten the extension time. For a 200 bp amplification product, an extension time of 15 to 20 seconds is sufficient. Excessive extension time will introduce unnecessary nonspecific PCR products!

Taq DNA polymerase is the most commonly used in PCR reactions, especially in PCR amplification to verify the target gene. Pyrococcus furiosus (PFU) polymerase is widely used in high-fidelity PCR reactions.

However, there are also some other polymerases that have different amplification efficiencies for different templates. For example: if your amplification template contains a high GC content (over 65%), Thermo Scientific's Accuprime G-C Rich DNA Polymerase will amplify more effectively!

When you purchase a tube of DNA polymerase, the package will include a tube of already optimized Buffer. Normally, following the instructions will not go wrong. However, we believe that as a researcher, it is necessary to understand the effects of Buffer components and concentrations on PCR efficiency. Because most Buffers are simply a mixture of salt ions (KCl and MgCl2) at a certain pH value.

The magnesium ion concentration can be adjusted to change the efficiency and fidelity of PCR. For Taq DNA polymerase, the optimized magnesium ion concentration is 1.5 to 2 mM, because other buffers and components required for the reaction may chelate magnesium ions, thereby requiring an increase in magnesium ion concentration. Ultimately, when setting the magnesium ion concentration, a small adjustment is made (approximately an increase of 0.5 mM).

Including primer length, GC content, Tm value,dimersand so on...Here is a brief introduction to optimizing primer concentration. If too much primer is added, it will increase nonspecific binding and primer dimers. We believe that setting the primer concentration at a lower level of 1 μM is recommended and will work much better. To improve specificity, the primer concentration can even be reduced to 0.1 μM, but this may reduce PCR yield.


The concentration of dNTPs affects not only the specificity of PCR but also the yield. Too high a concentration of dNTPs will reduce specificity, and too low may reduce yield.
Disclaimer:The content of the article is for reference only and does not constitute investment advice. The various articles published on this official account are mainly for sharing. If there is any infringement, please contact us and we will delete them.






Back to list